MOBILE QUALITY REEFER REPAIR(505) 386-1459 · 24/7 reefer dispatch

Why is my Carrier reefer unit leaking thick oil from the bottom of the compressor?

Carrier reefer unit · Albuquerque, NM · 2026-11

Call (505) 386-1459Request reefer service

What the driver reported

["carrier reefer leaking oil","thick oil under compressor","oil coming out of plastic pad on reefer bottom"]

What dispatch told the driver

When a Carrier reefer unit leaks thick compressor oil onto the bottom pad, the most common culprit is a failed compressor shaft seal, an oil cooler leak, or a cracked oil pressure line. Severe leaks can also come from a loose oil filter housing or damaged gasket around the oil pump. First, check your reefer oil sight glass to see how much oil remains in the compressor. Safely inspect around the shaft seal, oil cooler lines, and filter area using a flashlight to locate the wet source, taking care to keep hands clear of belts and moving pulleys. If the oil leak is active and severe, running the reefer unit without sufficient compressor oil will cause the compressor to seize, resulting in complete unit failure and potential cargo damage. If you are hauling temperature-sensitive freight, shut down the unit if oil is completely gone and call a mobile reefer technician immediately to pressure test, repair the leaking line or seal, and recharge the reefer oil before restarting.

What the technician found

Driver reported heavy thick oil leaking beneath the Carrier reefer compressor; specific leak point between the shaft seal, oil cooler, lines, filter, or pump was not confirmed on the call.

How it ended

unknown

Real calls handled by MTS dispatch. Names, phone numbers and prices are removed.

More real reefer calls

Real calls handled by MTS dispatch. Names, phone numbers and prices are removed.

Why does my reefer trailer shut down after a few minutes with a check evaporator airflow alarm?

2026-11

When a reefer unit displays a check evaporator airflow alarm and shuts down after running for five to seven minutes, the micro-controller is protecting the unit from freezing or overheating due to restricted air circulation across the evaporator coil. The mos…

My Thermo King reefer unit won't start and I think the battery is dead, what should I check?

Thermo King reefer unit · Miami, FL · 2026-11

When a Thermo King reefer unit fails to turn on or start, a dead or weak battery is one of the most common causes, especially if the unit previously gave low voltage warnings. Start by checking the battery connections to ensure the cables are clean, tight, an…

Why does my Carrier reefer unit keep throwing the main compressor belt?

Carrier reefer unit · 2026-11

When a Carrier reefer unit repeatedly throws or rips its main compressor belt, the issue usually stems from misaligned pulleys, a failing belt tensioner, worn compressor clutch bearings, or an overloaded compressor. A weak tensioner allows the belt to flap un…

How do I handle a ripped belt and required maintenance on a Carrier box truck reefer unit?

Carrier Supra reefer unit on box truck · Johns Island, SC · 2026-11

When a Carrier Supra reefer unit on a box truck suffers a ripped belt, cooling performance stops immediately, putting temperature-sensitive cargo at risk. A snapped or shredded belt is typically caused by normal wear and tear, incorrect belt tension, a seized…

Real reefer repair calls

Mobile Quality Reefer Repair is the mobile reefer repair line of MTS Mobile Truck Repair Service LLC: Thermo King and Carrier Transicold repair, alarms, refrigerant and reefer engines on US interstates, 24/7 · (505) 386-1459 · Request service · All highways · mtstruckservice.com
Call (505) 386-1459Request service