Why is my Carrier reefer unit not cooling and displaying alarm code 00028?

Carrier reefer · Lake Station, IN · 2026-11

Call (219) 552-1928Request reefer service

What the driver reported

["reefer not cooling","Carrier alarm code 00028","check refrigeration system code"]

What dispatch told the driver

A Carrier reefer displaying alarm code 00028 indicates a check refrigeration system warning, usually triggered when the unit fails to cool properly or maintain setpoint temperature. Common causes include low refrigerant levels from a leak, a sticking thermal expansion valve, restricted airflow across evaporator or condenser coils, or faulty pressure sensors. Drivers can start by checking the setpoint settings and visually inspecting the evaporator and condenser coils for ice accumulation or dirt blockage. Look along the refrigerant lines for any oily film, which typically indicates a freon leak. Ensure the compressor belt is intact and properly tensioned. If airflow is clear and belts are intact, a mobile reefer technician is needed to connect manifold gauges, check suction and discharge pressures, perform leak testing, and recharge or repair the refrigeration circuit.

What the technician found

Cause not confirmed on the call

How it ended

unknown

Real calls handled by MTS dispatch. Names, phone numbers and prices are removed.

More real reefer calls

Real calls handled by MTS dispatch. Names, phone numbers and prices are removed.

Why does my reefer trailer shut down after a few minutes with a check evaporator airflow alarm?

2026-11

When a reefer unit displays a check evaporator airflow alarm and shuts down after running for five to seven minutes, the micro-controller is protecting the unit from freezing or overheating due to restricted air circulation across the evaporator coil. The mos…

My Thermo King reefer unit won't start and I think the battery is dead, what should I check?

Thermo King reefer unit · Miami, FL · 2026-11

When a Thermo King reefer unit fails to turn on or start, a dead or weak battery is one of the most common causes, especially if the unit previously gave low voltage warnings. Start by checking the battery connections to ensure the cables are clean, tight, an…

Why does my Carrier reefer unit keep throwing the main compressor belt?

Carrier reefer unit · 2026-11

When a Carrier reefer unit repeatedly throws or rips its main compressor belt, the issue usually stems from misaligned pulleys, a failing belt tensioner, worn compressor clutch bearings, or an overloaded compressor. A weak tensioner allows the belt to flap un…

How do I handle a ripped belt and required maintenance on a Carrier box truck reefer unit?

Carrier Supra reefer unit on box truck · Johns Island, SC · 2026-11

When a Carrier Supra reefer unit on a box truck suffers a ripped belt, cooling performance stops immediately, putting temperature-sensitive cargo at risk. A snapped or shredded belt is typically caused by normal wear and tear, incorrect belt tension, a seized…