MOBILE QUALITY REEFER REPAIR(726) 208-4734 · 24/7 reefer dispatch

Why is my Carrier reefer unit losing temperature again after just being filled with refrigerant?

Carrier reefer unit · Converse, TX · IH-10 · 2026-11

Call (726) 208-4734Request reefer service

What the driver reported

["reefer temp raising","high temperature alarm","losing cooling capacity"]

What dispatch told the driver

When a Carrier reefer unit loses cooling performance shortly after being charged with refrigerant, you are dealing with a significant system leak. Refrigerant does not burn off or disappear during normal operation, so needing a major charge means freon is actively escaping. Common leak points on transport refrigeration units include vibration-cracked suction or discharge lines, worn compressor shaft seals, corroded evaporator or condenser coils, and leaking service valves. As a driver, you can perform a quick visual inspection around the reefer unit. Look for wet, oily residue along copper lines, hose crimps, and valve fittings, as compressor oil circulates with the refrigerant and collects at leak sites. Also verify that the reefer belt is tight, the condenser fans are blowing strong, and note any diagnostic alarm codes displayed on the controller screen. Because topping off refrigerant without finding the leak is only a temporary patch, the unit requires a professional technician. A tech will pressurize the system with nitrogen, pinpoint the leak with an electronic detector, repair the component, pull a deep vacuum, and recharge to exact factory specifications.

What the technician found

Carrier reefer unit previously required 11 pounds of freon in Louisiana and began losing temperature again in Texas; driver routed to local shop for leak inspection and repair

How it ended

unknown

Real calls handled by MTS dispatch. Names, phone numbers and prices are removed.

More real reefer calls

Real calls handled by MTS dispatch. Names, phone numbers and prices are removed.

Why does my reefer trailer shut down after a few minutes with a check evaporator airflow alarm?

2026-11

When a reefer unit displays a check evaporator airflow alarm and shuts down after running for five to seven minutes, the micro-controller is protecting the unit from freezing or overheating due to restricted air circulation across the evaporator coil. The mos…

My Thermo King reefer unit won't start and I think the battery is dead, what should I check?

Thermo King reefer unit · Miami, FL · 2026-11

When a Thermo King reefer unit fails to turn on or start, a dead or weak battery is one of the most common causes, especially if the unit previously gave low voltage warnings. Start by checking the battery connections to ensure the cables are clean, tight, an…

Why does my Carrier reefer unit keep throwing the main compressor belt?

Carrier reefer unit · 2026-11

When a Carrier reefer unit repeatedly throws or rips its main compressor belt, the issue usually stems from misaligned pulleys, a failing belt tensioner, worn compressor clutch bearings, or an overloaded compressor. A weak tensioner allows the belt to flap un…

How do I handle a ripped belt and required maintenance on a Carrier box truck reefer unit?

Carrier Supra reefer unit on box truck · Johns Island, SC · 2026-11

When a Carrier Supra reefer unit on a box truck suffers a ripped belt, cooling performance stops immediately, putting temperature-sensitive cargo at risk. A snapped or shredded belt is typically caused by normal wear and tear, incorrect belt tension, a seized…

Real reefer repair calls

Mobile Quality Reefer Repair is the mobile reefer repair line of MTS Mobile Truck Repair Service LLC: Thermo King and Carrier Transicold repair, alarms, refrigerant and reefer engines on US interstates, 24/7 · (726) 208-4734 · Request service · All highways · mtstruckservice.com
Call (726) 208-4734Request service