Why does my Carrier reefer unit keep shutting down and showing a temperature sensor fault code?

Carrier reefer unit · Memphis, TN · 2026-11

Call (901) 307-4664Request reefer service

What the driver reported

["Carrier reefer shuts down","temperature sensor fault code","reefer unit display screen error"]

What dispatch told the driver

When a Carrier reefer unit displays a sensor code and shuts down automatically, it is usually triggering a safety protocol to protect the internal engine and compressor. The most common cause is a failing or dirty temperature sensor that sends inaccurate readings to the main controller, leading the system to detect an out-of-range thermal condition. Another frequent culprit is low refrigerant level caused by a minor leak. When freon runs low, the system cannot achieve the target temperature, causing severe temperature fluctuations across the evaporator coil that trip sensor alarms and shut the unit down.

Before calling out a technician, check the wiring harness and connectors attached to the temperature sensors for corrosion, loose pins, or physical damage. Ensure the reefer doors are sealing properly and there are no airflow blockages inside the trailer cargo area. If visual checks look clean but the unit continues to log fault codes and shut off, a mobile reefer technician needs to connect diagnostic tools to test sensor resistance, check suction and discharge pressures, and recharge refrigerant if a leak is detected. Continuing to force the unit to run while it short-cycles can cause serious damage to the reefer compressor.

What the technician found

Dispatch reviewed fault code 100121 over the phone, indicating a temperature sensor issue or low refrigerant level causing the unit to shut down to protect itself. On-site diagnosis was not completed on the call.

How it ended

customer declined

Real calls handled by MTS dispatch. Names, phone numbers and prices are removed.

More real reefer calls

Real calls handled by MTS dispatch. Names, phone numbers and prices are removed.

Why does my reefer trailer shut down after a few minutes with a check evaporator airflow alarm?

2026-11

When a reefer unit displays a check evaporator airflow alarm and shuts down after running for five to seven minutes, the micro-controller is protecting the unit from freezing or overheating due to restricted air circulation across the evaporator coil. The mos…

My Thermo King reefer unit won't start and I think the battery is dead, what should I check?

Thermo King reefer unit · Miami, FL · 2026-11

When a Thermo King reefer unit fails to turn on or start, a dead or weak battery is one of the most common causes, especially if the unit previously gave low voltage warnings. Start by checking the battery connections to ensure the cables are clean, tight, an…

Why does my Carrier reefer unit keep throwing the main compressor belt?

Carrier reefer unit · 2026-11

When a Carrier reefer unit repeatedly throws or rips its main compressor belt, the issue usually stems from misaligned pulleys, a failing belt tensioner, worn compressor clutch bearings, or an overloaded compressor. A weak tensioner allows the belt to flap un…

How do I handle a ripped belt and required maintenance on a Carrier box truck reefer unit?

Carrier Supra reefer unit on box truck · Johns Island, SC · 2026-11

When a Carrier Supra reefer unit on a box truck suffers a ripped belt, cooling performance stops immediately, putting temperature-sensitive cargo at risk. A snapped or shredded belt is typically caused by normal wear and tear, incorrect belt tension, a seized…