Call (855) 450-1212Request reefer service["reefer set point 33 degrees","box temperature fluctuating between 28 and 46 degrees","reefer alarm came on","reefer temperature rose to 50 degrees"]
When a reefer unit set to 33 degrees fluctuates wildly between 28 and 46 degrees before triggering a high-temp alarm and reaching 50 degrees, several refrigeration components could be at fault. A common cause is an evaporator coil icing over due to a failing defrost cycle or stuck damper door, severely restricting airflow. Erratically fluctuating readings can also point to a faulty return air temperature sensor or thermistor sending bad signals to the control board. Additionally, low refrigerant, a failing expansion valve, or a slipping compressor belt will prevent the unit from maintaining set point.
Drivers should first inspect the trailer interior to ensure freight isn't blocking the air chute or return intake. Check if the evaporator coil is iced up and attempt a manual defrost cycle if possible. Also check that trailer door seals are intact. Because an active alarm and rising temp risk perishable cargo, a mobile reefer technician should be dispatched immediately to read fault codes, check refrigeration pressures, and diagnose the electrical control system.
Cause not confirmed on the call
unknown
Real calls handled by MTS dispatch. Names, phone numbers and prices are removed.
Real calls handled by MTS dispatch. Names, phone numbers and prices are removed.
When a reefer unit displays a check evaporator airflow alarm and shuts down after running for five to seven minutes, the micro-controller is protecting the unit from freezing or overheating due to restricted air circulation across the evaporator coil. The mos…
When a Carrier reefer unit repeatedly throws or rips its main compressor belt, the issue usually stems from misaligned pulleys, a failing belt tensioner, worn compressor clutch bearings, or an overloaded compressor. A weak tensioner allows the belt to flap un…
When a reefer unit display screen is completely blank and the unit fails to respond or turn on, the issue is almost always related to primary electrical power feed to the reefer microprocessor or control panel. The first thing a driver should check is the mai…
When a Carrier reefer unit starts up and immediately shuts down with a system problem warning, it typically points to a protective shutdown triggered by the unit controller. The most common causes include air in the fuel lines, low fuel pressure, low engine o…