Thermo King reefer · Sault Ste. Marie, ON · 2026-11
Call (855) 450-1212Request reefer service["Thermo King error code 86","Thermo King error code 87","reefer not cooling","pressure sensor going off"]
Thermo King alarm codes 86 and 87 typically point to issues within the discharge and suction pressure sensor circuits or extreme pressure readings. Code 86 indicates a discharge pressure sensor check or high discharge pressure alarm, while code 87 relates to the suction pressure sensor circuit or abnormal suction pressure. When these codes trigger simultaneously, the control board disables the compressor to protect the system, preventing the reefer from cooling. Before calling for service, inspect the wire harness connected to the pressure transducers on the compressor and discharge line for loose plugs, corrosion, or damaged wires. Check the condenser coil for severe dirt blockage, ice build-up, or debris restricting airflow, and ensure the condenser fan is spinning properly. If the wiring and airflow look fine, the problem is usually a failed pressure transducer, a damaged transducer wiring harness, or an actual severe refrigeration system fault such as a severe refrigerant leak or clogged expansion valve. Diagnostic computer software is required to read live transducer voltage and pressure readings to confirm whether the sensor failed or actual system pressure is out of spec.
Cause not confirmed on the call
customer declined
Real calls handled by MTS dispatch. Names, phone numbers and prices are removed.
Real calls handled by MTS dispatch. Names, phone numbers and prices are removed.
When a Carrier reefer unit on a straight truck repeatedly shuts down during pre-cooling, the unit's controller is likely triggering a safety shutdown. Common causes include clogged fuel filters causing fuel starvation, low engine oil pressure, low engine cool…
When a reefer unit displays a check evaporator airflow alarm and shuts down after running for five to seven minutes, the micro-controller is protecting the unit from freezing or overheating due to restricted air circulation across the evaporator coil. The mos…
When a Thermo King reefer unit fails to turn on or start, a dead or weak battery is one of the most common causes, especially if the unit previously gave low voltage warnings. Start by checking the battery connections to ensure the cables are clean, tight, an…
When a Carrier reefer unit repeatedly throws or rips its main compressor belt, the issue usually stems from misaligned pulleys, a failing belt tensioner, worn compressor clutch bearings, or an overloaded compressor. A weak tensioner allows the belt to flap un…