Reefer trailer cooling issue at market in Destin, FL
An emergency service request for a loaded reefer trailer not cooling in Destin, FL was canceled before an MTS technician could perform repairs.
Every case below is a real call to our 24/7 truck dispatch. We remove names, phone numbers, companies and prices, and keep what helps the next driver: the symptoms, what was checked on the call and what usually fixes it. Broken down right now? Call (855) 450-1212 or request service.
By state: Florida (5)
An emergency service request for a loaded reefer trailer not cooling in Destin, FL was canceled before an MTS technician could perform repairs.
A driver reported a Thermo King reefer start failure on a 2023 Volvo trailer in Post Falls, ID, but the call was canceled before service.
A caller reported a 2016 Great Dane trailer with a Carrier reefer unit not cooling in Lake Station, Indiana, but the job was canceled.

Driver asked: Why does my Carrier reefer shut off before reaching set temperature with high coolant temp code?
On the call: Driver checked the controller display which showed alarm code A00012 (high coolant temperature on Carrier Transicold unit). The unit starts and cools down to around 3 degrees F before shutting off to…
When a Carrier reefer unit starts up, begins cooling, and then shuts down with code A00012, the safety system is triggering due to high coolant temperature to protect the reefer engine and compressor from severe damage. The most common cause is a thermal… Full case →

Driver asked: Why is my Thermal King reefer making a clicking noise near the belt?
On the call: Driver reported a clicking noise coming from the belt area on a Thermal King reefer unit; suspected worn belt or failing tensioner pulley.
A clicking or metallic chattering noise coming from your Thermal King reefer belt area usually points to a failing belt tensioner pulley, a worn belt, or an accessory bearing starting to fail. When a belt tensioner spring or internal bearing breaks down, the… Full case →

Driver asked: Why is my Thermo King container reefer unit not cooling down even though there are no fault codes?
On the call: Cause not confirmed on the call
When a Thermo King container unit runs without displaying error codes but fails to pull down the temperature, the most common culprit is a low refrigerant charge caused by a small leak in the system. Other frequent causes include a restricted thermal… Full case →

Driver asked: My Thermo King reefer unit won't start and I think the battery is dead, what should I check?
On the call: Customer reported a Thermo King reefer unit was down and would not turn on, suspecting a dead battery due to prior low voltage warnings. Dispatch arranged a mobile service technician to replace the…
When a Thermo King reefer unit fails to turn on or start, a dead or weak battery is one of the most common causes, especially if the unit previously gave low voltage warnings. Start by checking the battery connections to ensure the cables are clean, tight… Full case →

Driver asked: Why is my Thermal King reefer cycling through start without cranking and showing an ETV circuit alarm?
On the call: Thermal King reefer repeatedly cycled start sequence without engine cranking. Display flashed Check ETV circuit and ECU failed to enable alarm messages. Unit had adequate fuel.
When a Thermal King reefer repeatedly cycles through its start sequence without turning the engine over, it points to a control system or safety interlock preventing crank. Alarms such as Check ETV Circuit and ECU Failed to Enable indicate the microprocessor… Full case →

Driver asked: Why does my Thermo King reefer start, run for 30 seconds, and then shut down with fuel alarms?
On the call: Cause not confirmed on the call
When a Thermo King reefer engine starts easily but shuts down after 30 to 40 seconds with fuel circulation or low fuel level alarms despite a full tank, fuel starvation or a safety shutdown circuit is triggering the issue. The most common cause is air getting… Full case →
Driver asked: Why is my Carrier reefer trailer not cooling well after sitting for two years?
On the call: Carrier reefer unit sat for two years and was not cooling properly. Dispatch informed the driver that refrigerant recovery and Freon service must be completed in a repair shop rather than roadside.
When a Carrier reefer unit sits unused for two years and fails to cool properly, the most common cause is refrigerant loss. Extended downtime allows compressor shaft seals and O-rings to dry out and seep Freon. Other common issues after long storage include… Full case →

Driver asked: Why does my Carrier reefer unit display a check refrigeration alarm and shut off after running for 10 minutes?
On the call: Carrier reefer unit triggered a check refrigeration alarm and shut down automatically after 10 minutes to protect the compressor from thermal damage; suspected refrigerant leak or faulty temperature…
When a Carrier reefer unit starts, runs for around 10 minutes, and then automatically shuts down with a check refrigeration unit alarm, it is usually triggered by a high discharge pressure or thermal protection trip. The most common cause is low refrigerant… Full case →

Driver asked: Why is my Thermo King reefer showing code 619 ECU relay fault with a new battery?
On the call: Cause not confirmed on the call
When a Thermo King reefer trips code 619 alongside a low battery voltage code, it indicates the control unit is detecting insufficient operating voltage or a failure in the ECU main relay circuit. Even with a brand-new battery installed, electrical issues… Full case →

Driver asked: Why does my Carrier reefer unit keep shutting down after running for five minutes with an alarm?
On the call: Cause not confirmed on the call
When a Carrier trailer reefer unit starts, runs for four or five minutes, and then shuts down with an alarm, it is usually triggering a safety shutdown. The most common causes include engine overheating from low coolant or a loose belt, low engine oil… Full case →
Driver asked: Why does my Carrier reefer unit shut down after running for five minutes with an alarm?
On the call: Checked fuel level (more than half tank). Driver attempted to identify alarm code on the display panel. Cause not confirmed on the call.
When a Carrier reefer starts up normally but shuts down after four to five minutes while triggering an alarm, the unit is usually executing a safety shutdown to protect the engine or compressor. A frequent cause is restricted fuel delivery due to clogged fuel… Full case →
Driver asked: My reefer fan belt snapped on the road, what should I do?
On the call: Driver reported a broken reefer fan belt that required replacement.
When a reefer fan belt snaps, the unit loses critical airflow needed to cool the condenser coils and maintain cargo temperatures. Common causes of belt failure include normal wear and tear, improper belt tension, misaligned pulleys, or a seized alternator or… Full case →
Driver asked: Why is my Carrier reefer unit not cooling and displaying alarm code 00028?
On the call: Cause not confirmed on the call
A Carrier reefer displaying alarm code 00028 indicates a check refrigeration system warning, usually triggered when the unit fails to cool properly or maintain setpoint temperature. Common causes include low refrigerant levels from a leak, a sticking thermal… Full case →

Driver asked: Why does my Carrier reefer unit start up and then shut down by itself?
On the call: Cause not confirmed on the call
When a Carrier reefer unit starts up and immediately shuts down with a system problem warning, it typically points to a protective shutdown triggered by the unit controller. The most common causes include air in the fuel lines, low fuel pressure, low engine… Full case →

Driver asked: Why is my Carrier reefer unit running intermittently with a yellow light bar and fault code?
On the call: Carrier reefer unit displayed a yellow light bar and ran intermittently with a fault code indicating a camshaft position sensor issue.
When a Carrier reefer unit runs intermittently, displays a yellow status light bar, and logs engine-related fault codes, the issue often stems from a failing camshaft position sensor, speed sensor, or associated wiring harness problems. The camshaft sensor… Full case →

Driver asked: Why is my reefer temperature fluctuating wildly and setting off an alarm when set to 33 degrees?
On the call: Cause not confirmed on the call
When a reefer unit set to 33 degrees fluctuates wildly between 28 and 46 degrees before triggering a high-temp alarm and reaching 50 degrees, several refrigeration components could be at fault. A common cause is an evaporator coil icing over due to a failing… Full case →

Driver asked: Why does my Carrier reefer unit keep shutting down and showing a temperature sensor fault code?
On the call: Dispatch reviewed fault code 100121 over the phone, indicating a temperature sensor issue or low refrigerant level causing the unit to shut down to protect itself. On-site diagnosis was not completed…
When a Carrier reefer unit displays a sensor code and shuts down automatically, it is usually triggering a safety protocol to protect the internal engine and compressor. The most common cause is a failing or dirty temperature sensor that sends inaccurate… Full case →

Driver asked: Why does my reefer unit just click and refuse to start after replacing the battery?
On the call: Reefer unit clicks when trying to start after a battery replacement; cause not confirmed on the call
When a reefer unit only clicks after installing a brand new battery, the issue is typically electrical or starter-related rather than a dead battery itself. The most common culprit is a bad ground connection or loose or corroded battery terminals installed… Full case →

Driver asked: Why does my Carrier reefer unit keep shutting off with a low suction superheat code?
On the call: The reefer controller showed low suction superheat warnings before shutting the unit down, pointing to a probable low refrigerant condition. Cause not confirmed on the call.
When a Carrier reefer unit repeatedly shuts down and displays a low suction superheat warning, it typically means the evaporator is not receiving enough refrigerant to operate safely. The most common cause is a refrigerant leak in the system, resulting in low… Full case →

Driver asked: Why is my Thermo King reefer showing alarm 841 and not starting after I refilled the fuel tank?
On the call: Thermo King reefer unit ran out of diesel fuel and displayed alarm code 841 for engine stall. After filling the tank, the unit would not restart due to air trapped in the fuel system.
When a Thermo King reefer unit runs completely out of fuel, it draws air into the fuel lines and injection pump, triggering alarm code 841 for an engine stall. Refilling the fuel tank alone will usually not start the unit because trapped air prevents diesel… Full case →
Updated 2026-11-24. Full write-ups are kept on our repair-answers library.
Real breakdown calls to our 24/7 dispatch, written up without names or prices. Updated every hour.
Customer: My Carrier reefer unit keeps shutting off over here in Alachua, Florida. Can you send someone out to check it?
MTS: Yes, we can service Carrier reefers in that area. Is the display panel giving you any fault codes when it shuts down?
Customer: Yeah, it says low suction superheat on the screen.
MTS: A low suction superheat code usually means the reefer is low on Freon. That causes the unit to overheat and automatically shut down to prevent compressor damage.